1999 PCED On Board Diagnostics II |
SECTION 5: Pinpoint Tests |
HG: Positive Crankcase
|
HG: Introduction |
| Yes | No |
|---|---|
| REINSTALL PCV valve. GO to HG2 . |
PCV valve is sticking.
REPLACE PCV valve. VERIFY a symptom no longer exists. |
| Yes | No |
|---|---|
| PCV System is OK. RETURN to Section 3 for other possible causes of vehicle symptoms. | System is leaking/plugged or Evaporative Emission System is leaking. GO to HG3 . |
Note: If the evaporative emission hose is not connected to the PCV hose, follow the No Action to Take (refer to VECI decal).
| Yes | No |
|---|---|
|
PCV system is OK. GO to Evaporative Emission System Testing.
For all others: GO to Pinpoint Test Step HX47 . Flexible fuel vehicles: GO to Pinpoint Test Step HX94 . |
CHECK for vacuum leaks/obstruction in the PCV system (such as oil cap, PCV valve, hoses, cut grommets, valve cover bolt torque/gasket leak). REPAIR as necessary. |