Section 14-02: Generator, Integral Regulator—Internal Fan Type | 1994 Mustang Workshop Manual |
DESCRIPTION AND OPERATION
Generator Circuit
Circuit Description
Battery Positive Voltage (B+) Output
The generator output is supplied:
- Through battery positive voltage (B+) output connection.
- To the battery (10653)
and electrical system.
'I' Circuit
The I' circuit, or ignition switch circuit is used to turn on:
- Generator regulator (10316).
- Ignition switch (11572) which is powered up with the ignition switch
in the RUN position.
- The indicator circuit if
there is a fault in the charging system operation or associated wiring circuits.
'A' Circuit
The 'A' circuit, or battery sense circuit is used:
- To sense battery voltage.
- By the generator regulator
to determine generator output.
- To supply power to the generator field coil.
The 'A' circuit is:
- Connected back to the load distribution point.
- A protected circuit.
'S' Circuit
'S' circuit, or stator circuit is:
- Used to feedback a voltage signal from the generator (GEN) (10300)
to the generator regulator
.
- Typically one-half battery voltage.
- Used by the generator regulator
to turn off the indicator.