Remove two upper retaining screws from the instrument cluster bezel.
Remove the instrument cluster bezel.
Remove four retaining screws from instrument cluster panel (042A82).
Pull the instrument cluster (10849) away from the instrument panel (04320)
. Disconnect the two cluster printed circuit connectors from their
receptacles in the instrument cluster back plate (10848).
Remove instrument cluster.
CAUTION: If gauges are being removed from the cluster assembly, do not remove
the gauge pointer: magnetic gauges cannot be recalibrated.
Installation
Connect the two cluster printed circuit connectors to their receptacles in
the instrument cluster back plate.
Position the instrument cluster to the instrument panel
. Install the four retaining screws.
Install instrument cluster bezel. Install two upper retaining screws to
instrument cluster bezel cover.