Section 12-00: Climate Control System—Service | 1994 Mustang Workshop Manual |
The refrigerant system has a high-pressure (discharge) and a low-pressure
(suction) gauge port valve. They provide access to both sides (high-pressure
and low-pressure) of the system for service hoses and a manifold gauge set so
system pressures can be read.
| Model | Description |
|---|---|
| 063-00003 | Safety Shield Goggles |
| 161-R0010 | R-134a Halogen Leak Detector |
| 078-00850 | R-134a Service Center |
| 176-R032A | R-134a Manifold Gauge Set |
| 176-R0026 | R-134a Low Side Quick Disconnect |
| 176-R0027 | R-134a High Side Quick Disconnect |
| 176-00034 | 3.0 CFM R-134a Vacuum Pump |
| 021-00012 | Radiator/Heater Core Pressure Tester |
R134a systems require the use of special servicing equipment designed specifically for R134a systems. R-12 servicing equipment cannot be used when servicing R134a A/C systems. R134a special service equipment includes recovery/recycling/recharging station, R134a leak detector, R134a vacuum pump and R134a manifold gauge set.
CAUTION: Do not use R-12 special tools and equipment when servicing a R134a
system. Doing so may cause damage to the R134a A/C system.