Tighten manifold retaining bolts to 18-23 Nm (14-16 lb-ft).
Add refrigerant and leak test manifold O-ring seals using Rotunda Leak
Detector 055-00015 or equivalent.
If no leaks are found during leak test, manifold O-ring seals are good.
If a leak is found at manifold and manifold bolts are tightened to 18-23 Nm
(14-16 lb-ft), install new manifold O-ring seals following
procedure under Suction and Discharge Manifold Removal and Installation, then
repeat leak test procedure.