Section 12-02: Heating and Defrosting
1993 Mustang Workshop Manual
SPECIFICATIONS

Specifications

SYSTEM PROTECTION
Description Specification
System Protection 15 Amp Fuse (LB) in Fuse Panel 9
Blower Motor Speed LO 2.2 Amps/5.1 Volts
Medium 3.7 Amps/7.3 Volts
HI 9.2 Amps/12.8 Volts
Illumination Control Assy. One—.75 CP-1892 Bulb
One—1 CP-161 Bulb



TORQUE SPECIFICATIONS
Description Nm Lb-Ft Lb-In
Heater Hose Clamps 1.36-2.50 13-22