Section 03-01B: Engine, 5.0L HO and 5.0L Cobra
1993 Mustang Workshop Manual
DISASSEMBLY AND ASSEMBLY

 CAUTION: Do not oil threads that require oil resistant or water resistant sealer.

When installing nuts or bolts, oil the threads with light weight engine oil.

Refer to Section 03-00 for Cleaning and Inspection procedures.

Hydraulic Tappet

 

The internal parts of each hydraulic tappet assembly are matched sets. Do not intermix the parts. Keep the assemblies intact until they are to be cleaned. Tappets should always be tested after assembly. Refer to the cleaning, inspection and test procedures in Section 03-00.

Tools Required:

 

Disassembly

Disassemble and assemble each tappet separately. Identify the tappet assemblies so they can be installed in their original bores.

  1. Grasp the lock ring with needlenose pliers to release it from the groove. It may be necessary to depress the plunger to fully release lock ring.
  1. Remove the push rod cup, metering valve (disc), plunger and spring.
  1. Remove the plunger assembly, the check valve and the check valve retainer and plunger spring. Carefully remove the plunger spring, the check valve retainer and the check valve disc from the plunger.
 

Assembly

  1. Place the plunger upside down on a clean work bench.
  1. Place the check valve (disc or ball check) in position over the oil hole on the bottom of the plunger. Set the check valve spring on top of the check valve (disc or ball check).
  1. Position the check valve retainer over the check valve and spring and push the retainer down into place on the plunger.
  1. Place the plunger spring, and then the plunger (open end up) into the tappet body.
  1. Position the metering valve (disc) in the plunger, and then place the push rod cup in the plunger.
  1. Depress the plunger, and position the closed end of the lock ring in the groove of the tappet body. With the plunger still depressed, position the open ends of the lock ring in the groove. Release the plunger, and then depress it again to fully seat the lock ring.
  1. Use the Hydraulic Tappet Leakdown Tester TOOL-6500-E or equivalent to fill the tappets with test fluid.