Drain the cooling system and remove the threaded draincock assembly from
the radiator.
Inspect pipe threads on the draincock assembly and the threaded draincock
boss in the radiator tank.
If the boss threads are damaged, service them with a 6.4mm (1/4 inch) pipe
tap. If the threads are damaged beyond service, install a new draincock boss
(Part No. 8120) in the radiator tank.
Apply Pipe Sealant with Teflon® D8AZ-19554-A
(ESG-M4G194-A and ESR-M18P7-A) or equivalent to the draincock threads and
install the draincock. Tighten the draincock to 16-20 Nm
(12-14 lb-ft).